A new transient thermal fouling probe for cross flow tubular heat exchangers - IMT Mines Albi-Carmaux Accéder directement au contenu
Article Dans Une Revue International Journal of Heat and Mass Transfer Année : 2009

A new transient thermal fouling probe for cross flow tubular heat exchangers

Résumé

The present probe is developed in order to accurately estimate in situ not only the convective exchange coefficient but also the fouling thickness of heat exchangers from a reliable transient state estimation method.The originality of the estimation method consists in considering a global response time of the system in fouling conditions to be compared to clean conditions. The sensitivity function is then built from the experimental signal without precise knowledge about the model or the absolute thermophysical properties. The reliability of the method is demonstrated in theoretical cases and with calibrated experiments.
Fichier principal
Vignette du fichier
A_new_transient_thermal_fouling_probe.pdf (385.71 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01651393 , version 1 (07-11-2019)

Identifiants

Citer

L. Perez, Bruno Ladevie, P. Tochon, J.C. Batsale. A new transient thermal fouling probe for cross flow tubular heat exchangers. International Journal of Heat and Mass Transfer, 2009, 52 (1-2), pp.407 - 414. ⟨10.1016/j.ijheatmasstransfer.2008.05.029⟩. ⟨hal-01651393⟩
162 Consultations
191 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More